4 Instructions 4.2.5 Step Sequential Control
STL
S
20
Y
2
Y3
Y
3
STL
STL
STL
S
21
S
22
S
Executed
Not executed
State number
Forward rotation
Reverse rotation
Y002
Y001
Y
0
Y
1
S20
S
21
S
30
S32
S
10
T2
K
20
T2 K5
T2 K30
Not allowed
STL
Y0
Y1
Y2
STL
internal
bus
X3
Use the STL
instruction marker
If the S contact of the STL instruction is connected
,
the circuit connected to
this contact becomes active
. If the S contact is disconnected
,
the circuit
becomes inactive
.
The instruction is no longer executed
(
in the jump state)
after a scan cycle
.
Different S states may correspond to the same output element
(
for example
,
Y
3).
When S
21 or S
22 is connected
, Y3 is output. The issue of dual coil
processing also exists in the same S state. Special attention is required.
The S state number cannot be used repeatedly
.
Output interlock
:
Two states are both connected for a period of time
(
one scan
cycle
)
during state transition. To prevent simultaneous
connection of a pair of outputs that cannot be connected at
the same time
,
configure external interlock for the PLC and
configure interlock for the corresponding program.
Repeated use of timers
Like output coils,
timer coils can be used to program the same
element in different states, but programming in adjacent
states is not allowed; otherwise, timer coils are not
disconnected during process transfer and the current value
cannot be reset
.
Output driving
After the LD or LDI instruction is written to the intra
-
state bus
,
instructions that do not need contacts can no longer be used,
as shown in the figure on the left
. Use the method shown in the
following figure to modify the circuit
.
Locations of MPS,
MRD,
and MPP for stack operation
The MPS
, MRD,
and MPP instructions cannot be used
directly in the STL internal bus in intra
-state mode. A program
must be compiled after the LD or LDI instruction
,
as shown in
the figure on the left.
State transition method
The OUT and SET instructions have the same function
(automatic reset of the transition source
) for the state
(S
) after
the STL instruction. Both instructions have the self
-hold
function
.
However, the OUT instruction executes transition to the
isolated state in SFC
.
S
10
STL
S45
Position
change
Transition
condition
SET
S42
Transition to the next
state
Transition to the
isolated state
X
4
S10
STL
Y1
Y2
Y3
STL
internal
bus
X3
X
2X0
X
4
MPS
MPD
MPP
LD X0
S10
STL
Y
0
Y
1
Y
2
Insert an NC
contact
M
8000
X
3
S10
STL
Y0
Y2
Y1
Position change
X
3
Or
S33
T
1

Table of Contents