Chapter 7 Function Code Table IS620P User Manual
- 166 -
Function
Code
Parameter
Name
Setting Range Unit Default
Effective
Time
Property
Control
Mode
H03 09
DI4 logic
selection
Input polarity: 0–4
0: Low level active
1: High level active
2: Rising edge active
3: Falling edge active
4: Both rising edge and
falling edge active
- 0 Upon stop
During
running
-
H03 10
DI5 function
selection
0–37 - 1 Upon stop
During
running
-
H03 11
DI5 logic
selection
Input polarity: 0–4
0: Low level active
1: High level active
2: Rising edge active
3: Falling edge active
4: Both rising edge and
falling edge active
- 0 Upon stop
During
running
-
H03 12
DI6 function
selection
0–37 - 12 Upon stop
During
running
-
H03 13
DI6 logic
selection
Input polarity: 0–4
0: Low level active
1: High level active
2: Rising edge active
3: Falling edge active
4: Both rising edge and
falling edge active
- 0 Upon stop
During
running
-
H03 14
DI7 function
selection
0–37 - 3 Upon stop
During
running
-
H03 15
DI7 logic
selection
Input polarity: 0–4
0: Low level active
1: High level active
2: Rising edge active
3: Falling edge active
4: Both rising edge and
falling edge active
- 0 Upon stop
During
running
-
H03 16
DI8 function
selection
0–37 - 31 Upon stop
During
running
-
H03 17
DI8 logic
selection
Input polarity: 0–4
0: Low level active
1: High level active
2: Rising edge active
3: Falling edge active
4: Both rising edge and
falling edge active
- 0 Upon stop
During
running
-
H03 18
DI9 function
selection
0–37 - 0 Upon stop
During
running
-

Table of Contents