IS620P User Manual                                                                                     Chapter 7 Function Code Table
- 167 -
Function 
Code
Parameter 
Name
Setting Range Unit Default
Effective 
Time
Property
Control 
Mode
H03 19
DI9 logic 
selection
Input polarity: 0–4
0: Low level active
1: High level active
2: Rising edge active
3: Falling edge active
4: Both rising edge and 
falling edge active
- 0 Upon stop
During 
running
-
H03 34
Function 
allocation 3 of 
DIs that are 
set to ON and 
effective
0–0xFFFF
Bit0: FunIN.33
Bit1: FunIN.34
……
Bit15: FunIN.48
- 0
Power-on 
again
During 
running
-
H03 35
Function 
allocation 4 of 
DIs that are 
set to ON and 
effective
0–0xFFFF
Bit0: FunIN.49
Bit1: FunIN.50
……
Bit15: FunIN.64
- 0
Power-on 
again
During 
running
-
H03 50 AI1 offset -5000 to 5000 mV 0 Immediate
During 
running
-
H03 51
AI1 lter time 
constant
0–655.35 ms 2.00 Immediate
During 
running
-
H03 53 AI1 dead zone 0–1000.0 mV 10.0 Immediate
During 
running
-
H03 54 AI1 zero drift -500.0 to 500.0 mV 0.0 Immediate
During 
running
-
H03 55 AI2 offset -5000 to 5000 mV 0 Immediate
During 
running
-
H03 56
AI2 lter time 
constant
0–655.35 ms 2.00 Immediate
During 
running
-
H03 58 AI2 dead zone 0–1000.0 mV 10.0 Immediate
During 
running
-
H03 59 AI2 zero drift -500.0 to 500.0 mV 0.0 Immediate
During 
running
-
H03 80
Speed 
corresponding 
to 10 V
0–6000 rpm rpm 3000 Immediate At stop -
H03 81
Torque 
corresponding 
to 10 V
1.00–8.00 times of 
rated torque
Times 1.00 Immediate At stop -