Loading...
IS620P User Manual Chapter 7 Function Code Table
- 173 -
Function
Code
Parameter
Name
Setting Range Unit Default
Effective
Time
Property
Control
Mode
H05 31
Mode of home
return
0: Forward home
return, deceleration
position and home
as home switches
1: Reverse home
return, deceleration
position and home
as home switches
2: Forward home
return, deceleration
position and home
as motor Z signals
3: Reverse home
return, deceleration
position and home
as motor Z signals
4: Forward home
return, deceleration
position as home
switch and home as
motor Z signal
5: Reverse home
return, deceleration
position as home
switch and home as
motor Z signal
6: Forward home
return, deceleration
position and home
as forward limit
switches
7: Reverse home
return, deceleration
position and home
as reverse limit
switches
8: Forward home
return, deceleration
position as forward
limit switch and
home as motor Z
signal
9: Reverse home
return, deceleration
position as reverse
limit switch and
home as motor Z
signal
- 0 Immediate At stop P