Chapter 7 Function Code Table IS620P User Manual
- 174 -
Function
Code
Parameter
Name
Setting Range Unit Default
Effective
Time
Property
Control
Mode
H05 32
Speed of home
switch signal
at high-speed
searching
0–3000 rpm 100 Immediate
During
running
P
H05 33
Speed of home
switch signal
at low-speed
searching
0–1000 rpm 10 Immediate
During
running
P
H05 34
Acceleration/
Deceleration
time at home
searching
0–1000 ms 1000 Immediate
During
running
P
H05 35
Time of home
searching
0–65535 ms 10000 Immediate
During
running
P
H05 36
Mechanical
home offset
-1073741824 to
1073741824
Reference
unit
0 Immediate
During
running
P
H05 38
Servo pulse
output source
0: Encoder
frequency-division
output
1: Reference pulse
synchronous output
2: Frequency-
division and
synchronous output
forbidden
- 0
Power-on
again
At stop P
H05 39
Electronic
gear ratio
switchover
condition
0: Enabled after
position reference
pulse remaining 0
for 10 ms
1: Enabled in real
time
- 0 Immediate At stop P