96 Intel
®
RAID Software Users Guide
7. This is supported only on a full installation of Intel
®
RAID Web Console 2; standalone,
client-only, and server-only modes do not support VMWare ESX3i management.
8. Supported on following guest operating systems:
Windows Server 2003* and Windows Server 2008*
Linux RHEL 4 and 5
9. The following describes the status of components related to VMWare ESX3i:
—Intel
®
RAID Web Console 2 client GUI is supported.
There is no support for Monitor Configurator; you cannot configure the severity of
the AENs.
There is no pop-up service support.
There is no email and system log support.
Monitor service support is not available.
10. For Red Hat Enterprise Linux 5, you must create the following symbolic links:
Note: This step is not required for Intel
®
RAID Web Console 2 version 2.90-02 or later.
cd /usr/lib on RHEL 5
Search for libcrypto, libssl and libsysfs libraries as follows:
ls -lrt libcrypto*, ls -lrt libssl*, ls -lrt libsysfs*
If the files libcrypto.so.4, libssl.so.4, and libsysfs.so.1 are missing,
manually create sym links as follows:
ln -s libcrypto.so libcrypto.so.4
ln -s libssl.so libssl.so.4
ln -s libsysfs.so libsysfs.so.1
If the '.so' files are not present in the /usr/lib directory, create a link with the
existing version of the library. For example, if
libcrypto.so.6 is present and
libcrypto.so is not, create the link as follows:
ln -s libcrypto.so.6 libcrypto.so.4
Running Intel
®
RAID Web Console 2 on VMWare ESX 3.5i U2
If you are using VMWare ESX 3.5i U2, perform the following steps to make Intel
®
RAID
Web Console 2 work:
1. Open the maintenance console/shell in ESX3.
a. Press ALT+F1.
A shell without any prompt appears.
b. Type unsupported (all lowercase) and press ENTER.
Typed text is not prompted back.
c. Enter your password when prompted.
There is no password by default for the shell. If you have set any password from the
"yellow" screen (DCUI), use that password.
You are prompted (#) next.
2. Enable ssh for remote copy.

Table of Contents

Other manuals for Intel SC5650BCDP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SC5650BCDP and is the answer not in the manual?

Intel SC5650BCDP Specifications

General IconGeneral
BrandIntel
ModelSC5650BCDP
CategoryServer
LanguageEnglish

Related product manuals