4. Cover the ber-opc cable connector with the rubber safety cap.
Fiber-Opc Cable Maintenance for an MX10004 Router
To maintain ber-opc cables in an MX10004 router:
• When you unplug a ber-opc cable from a transceiver, place rubber safety caps over the transceiver
and on the end of the cable.
• Anchor the ber-opc cable to avoid stress on the connectors. When you aach a ber-opc cable
to a transceiver, be sure to secure the ber-opc cable so that it does not support its own weight as
it hangs to the oor. Never let a ber-opc cable hang free from the connector.
• Do not bend ber-opc cables beyond their minimum bend radius. Bending the cables beyond their
minimum bend radius can damage the cables and cause problems that are dicult to diagnose.
• Frequent plugging and unplugging of ber-opc cables in and out of opcal instruments can damage
the instruments, which are expensive to repair. Aach a short ber extension to the opcal
equipment. Any wear and tear due to frequent plugging and unplugging is then absorbed by the
short ber extension. This extension is easier and less expensive to replace than the opcal
instruments.
• Keep ber-opc cable connecons clean. Microdeposits of oil and dust in the canal of the transceiver
or cable connector can cause loss of light, reducon in signal power, and possibly intermient
problems with the opcal connecon.
To clean the transceiver canal, use an appropriate ber-cleaning device such as RIFOCS Fiber Opc
Adaptor Cleaning Wands (part number 946). Follow the direcons in the cleaning kit you use.
Aer you clean the transceiver, make sure that the connector p of the ber-opc cable is clean. Use
only an approved alcohol-free ber-opc cable cleaning kit such as the Cletop-S® Fiber Cleaner
™
.
Follow the direcons in the cleaning kit you use.