Table 50: Set the JNP10K-PWR-AC2 DIP Switches
Switch State Descripon
1 On INP0 is present.
O INP0 is not present.
2 On INP1 is present.
O INP1 is not present.
3 On Enabled for 30-A feed; 5000 W is for a single feed, and 5500 W is for
dual feeds.
O Enabled for 20-A feed; power supply capacity is 3000 W.
14. If the AC power source outlet has a power switch, turn it o before plugging in the AC power cord
to the power outlet.
15. Verify that the INP1 and INP2 LEDs on the power supply faceplate are lit and are on steadily.
16. Press the power switch to the on (|) posion.
Remove a JNP10K-PWR-AC2 Power Supply
Before you remove a JNP10K-PWR-AC2 power supply from the chassis:
Review how to prevent ESD damage. See "Prevenon of Electrostac Discharge Damage" on page
263.
Ensure that you have the following parts and tools available:
Heat-protecve gloves able to withstand temperatures of 158° F (70° C)
Electrostac discharge (ESD) grounding strap
Phillips (+) screwdriver, number 1
Replacement power supply or a cover for the power supply slot
151