Keysight N9927-90001 User’s Guide 107
NA (Network Analyzer) Mode
NA Mode Settings
Font Size – Choose either Big or Super Big. Super Big marker readout #3
will cover some of the measurement grid.
Trace Settings - For each possible trace (1, 2, and 3) select from the
following:
Measurement – S-Parameter or Receiver measurement to display.
S11 is default. Learn more in “About S-parameters” on page 87.
Meas FormatLog is default. Learn more in “Format” on page 94.
Bandwidth (ON) – Marker readout for marker bandwidth search.
OFF is default. Learn how to set BW parameters in “How to Search
with Markers” on page 604.
Big Readout - For each marker readout (1, 2, and 3), select from the
following:
Marker # - Enter a number from 1 to 6 to create the marker. 1 is
created by default.
Trace # - The marker# is created on this trace. Tr1 is selected by
default. The corresponding Num Traces must first be selected. For
example, to create a marker on Trace 3, first select Num Traces = x3.
Format – Format for the marker readout. Select Default to make the
marker readout format the same as the display format. Default is
selected by default.
Mkr Tracking – ON: Select the parameter to track on the standard
Marker Search menu. OFF is selected by default. When set to ON,
Peak tracking is set by default. Learn about Marker Tracking in
“Marker Functions” on page 611.
State – Choose from Normal, Delta, or OFF. The default marker (1) is
created in Normal. Learn more in “Marker Functions” on page 611.
Enabled – Turns the Big Readout of the corresponding marker ON and
OFF. The default marker (1) is set ON by default.
Notes:
To move a marker, press Marker, then Marker, then scroll to the marker
number to be moved. The new marker position can NOT be saved with the A
or B display state.
Settings that are NOT listed above are NOT affected by the recalled display
states.
Changes to the above settings outside the Big Readout menu will be
overwritten when Big Readout (A or B) is selected. For example, suppose
the display format for the B state is Log. If you change the display format to
Lin using the standard menu (Meas 1, Format), the setting will show on the
display. But if you then use the Big Readout (A | B | OFF) setting, when B is
recalled, the Lin setting will be overwritten with the original Log setting.

Table of Contents

Other manuals for Keysight Technologies FieldFox N9938A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies FieldFox N9938A and is the answer not in the manual?

Keysight Technologies FieldFox N9938A Specifications

General IconGeneral
BrandKeysight Technologies
ModelFieldFox N9938A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals