EasyManuals Logo

Keysight Technologies FieldFox N9938A User Manual

Keysight Technologies FieldFox N9938A
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #520 background imageLoading...
Page #520 background image
520 Keysight N9927-90001 User’s Guide
AM/FM Metrics (SA Only and Option 355)
Interpreting AM/FM Metrics Error Messages
Test Tone Not Found - Example
The following response had the following settings:
Source CF: 140 MHz
FM Deviation: 18 kHz
Modulation Rate: 1 kHz
Reasons for error:
Frequency span of 1.0 MHz is too wide
No side lobes displayed, so test tone not found
Figure 25-7 Test Tone Not Found - Example

Table of Contents

Other manuals for Keysight Technologies FieldFox N9938A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies FieldFox N9938A and is the answer not in the manual?

Keysight Technologies FieldFox N9938A Specifications

General IconGeneral
BrandKeysight Technologies
ModelFieldFox N9938A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals