EasyManua.ls Logo

Kinco FD5 Series - RS485 Communication Parameters

Kinco FD5 Series
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kinco FD5 使用手
第十章 通讯连接
161
10.2.2 RS485 communication parameters
Table 10-3 RS485 communication parameters setting
LED display
Internal
address
Name
Meaning
Default
d5.01
100B0010
ID_Com
Station No.
Station No., to change this
parameter, you need to save
it with the address d5.00
and restart it later
The
station number can be
changed by the DIP switch
under the panel
. Details
refers to Chapter 3.8
1
d5.18
2FE20010
RS485 baud rate
Used to set the baud
rate of RS485
value baud rate
1080———9600
540———19200
270———38400
90————115200
Note: need to save and restart.
540
d5.19
65100C08
RS485 protocol
selection
0
use
Modbus
communication protocol
1use RS232
communication
protocol
Note: need to save and
restart
0
65100E10
RS485 Mod
0008
data bit
=8
, stop
bit
=1
No parity check
0009data bit=8, stop bit=2
No parity check
0008

Table of Contents