Kinco FD5 使用手
第五章 KincoServo 机使指南
72
bit
2
1
use mask
23000E20
),
AND gate
Note: You can no longer use the up
and down arrows on the oscilloscope
page to set the trigger edge to
prevent conflicts.
2300.12
Uint32
Trigger source
Oscilloscope Trigger Object
Dec
2300.13
Int32
Trigger level
Oscilloscope Trigger level
Dec
5.7 Error display and error history
Error
ClickController”
->
Error displayor click
buttonwhich turns red if an
error occurs
),The Error Display window appears. It shows the last errors.
Figure 5-14 Error display window
Error history
ClickController”
->
Error history”
The error history window will pop up and
display the last 8 error messages, including error word, bus voltage, speed, current, temperature,
working mode, and power tube status. The most recent historical failure is displayed on the first
line.
Figure 5-15 error history display window