Communication
encoder data reset
write:
1: clear encoder status
2: read fault word
3: Clear encoder status and
multi-turn data
8: Reset status flag
9: Clear multi-lap data
10: write 8 and 9
read:
bit 0: 1 = Commands can be
entered
bit 1: 1 = The last
command is executed
Speed in jog mode,unit
rpm
0:default
1:turn on remote node
40
:
Compatible with 2S panel
parameter flags
9.1 F001
This panel menu contains all controller values which can be shown by the LED display when it’s in the monitor mode
(see 4.2) and no error or warning is shown. On the LED panel, select the panel address of the value to be displayed
and press SET. After leaving the menu, the selected value is displayed. To make this selection permanent it must be
saved through d2.00 in F002.
Table 9-1-2: Panel F001 setting
Firmware version, display at the LED.
Displays the rate of real iit and max iit
of the motor.
Display the rate of real iit and max iit
of the controller.
Display the rate of real power and
rated power of the chopper.
temperature of controller, unit: ℃,