0x0F/0x2F:
Used when
operation_mode
is -3, 3, -4, 4
and position flow mode
0x2F->0x3F: Activate the absolute position
command, the absolute positioning command
will not be executed immediately according to
the change of the target position, it is used when
the operation_mode is 1
0x4F->0x5F:
Activate the relative position command,
used when the
operation_mode
is 1
0x103F:
Immediately execute the absolute positioning
command according to the target position change,
used when the
operation_mode
is 1
0x0F->0x1F: Used when starting to find the origin in 6
mode
0x06->0x86: Used when resetting drive faults
0x06: Loosen the shaft, turn off the drive enable
If Operation Mode Sel function is configured to DIN,
Operation_Mode(6060.00)=Din_Mode0 when Din_Internal=0;
Operation_Mode=Din_Mode1 when Din_Internal=1