第六章 工作模式介绍
80
-4: Pulse mode
4: Torque Mode
D0.01
6040.00
10
Controlword
0x0F/0x2F:
Used when
operation_mode
is -3, 3, -4, 4
and position flow mode
0x2F->0x3F: Activate the absolute position
command, the absolute positioning command
will not be executed immediately according to
the change of the target position, it is used when
the operation_mode is 1
0x4F->0x5F:
Activate the relative position command,
used when the
operation_mode
is 1
0x103F:
Immediately execute the absolute positioning
command according to the target position change,
used when the
operation_mode
is 1
0x0F->0x1F: Used when starting to find the origin in 6
mode
0x06->0x86: Used when resetting drive faults
0x06: Loosen the shaft, turn off the drive enable
607A.00
20
Target location
target absolute/relative position
6081.00
20
trapezoidal
velocity
Contour velocity in position mode
6083.00
20
Profile_Acc
Profile acceleration, profile deceleration, for Operation_Mode 1
and 3
6084.00
20
Profile_Dec
60FF.00
20
Target speed
Target speed in 3 operation_mode and -3 operation_mode
6071.00
10
Target
torque %
Target torque as a percentage of rated torque
6073.00
10
Target current
limit
Drive output current limit
D3.16
2020.0D
8
Din_Mode0
If Operation Mode Sel function is configured to DIN,
Operation_Mode(6060.00)=Din_Mode0 when Din_Internal=0;
Operation_Mode=Din_Mode1 when Din_Internal=1
D3.17
2020.0E
8
Din_Mode1