Kinco FD5 使用手
第六章 工作模式介绍
88
2020.13
20
Din_pos[7]
D3.40
2FF1.01
8
Din_position_sel
ectL
Select the position segment L to be set (L range
is 0-7, corresponding to the internal position
segment 0-7 in turn)
D3.41
2FF1.02
10
Din_position_M
Number of pulses set in position segment (L)
=M*10000+N
D3.42
2FF1.03
10
Din_position_n
For example
The configuration interface of I/O is shown in the following figure
Figure 6-2: DIN Configuration window
Figure 6-3 DOUT Configuration window
Table 6-15 DIN Location mode setting
Digital tube
key address
Home
address
Bits
Name
Descriptio
n
D3.17
2020.0E
Operation mode choose 1
1
2020.02
Din Position [1]
User define
DEC
2020.06
Din Speed [1]
User define
rpm
6083.00
Profile_ acceleration
User define
rps/s
6084.00
Profile_ deceleration
User define
rps/s
After enabling, select the position segment to go, the simulation command is activated, the drive executes
the program of the selected position segment, and outputs the multi-function signal 0 after reaching the Din
position [1].