GL16 Installation
2-9
8. Electrically ground the unit by connecting
the green fourth wire to the grounding lug
at the top left of the box (Figure 2-14).
9. Make sure the other end of the green
ground wire is properly grounded.
WARNING
The unit must be properly
grounded to ensure
operator safety.
10. Remove the temporary wires and connect
the three electric supply power wires to
the main disconnect switch terminals L1,
L2, and L3 (Figure 2-14).
WARNING
Do not turn on the electrical
supply until all wiring
is complete.
Figure 2-14: Connect supply power to L1, L2, L3,
and ground inside the electrical box.
L1 L2 L3
Ground
Sail Switch and Exhaust Blower Motor
Connection
1. The electrical wires for the sail switch and
exhaust blower motor are routed through
greenfield or flexible conduit. Run the
greenfield through the clips on the top rear
of the canopy and down the back of the
left end frame to the top of the main elec-
trical box (Figure 2-15).
2. The electrical connections for the exhaust
blower motor are made at the terminal
strip in the upper left corner of the main
electrical box (Figure 2-16). Connect the
three wires for the exhaust blower motor
to the terminals labeled L16, L17, and L18.
To connect a wire:
a) Insert a 1/8" slotted screwdriver into
the square hole just under the round
wire terminal hole.
b) Push the screwdriver into the square
hole until there is a soft click.
c) Push the wire into the round hole as
far as it will go.
d) Remove the screwdriver.
e) Pull gently on the wire to make sure it
is securely attached.
Required Tools
1/8" slotted screwdriver
Figure 2-15: Route wires for the sail switch and
exhaust blower motor in the
greenfield through the clips on the
top rear of the canopy.

Table of Contents