EasyManua.ls Logo

LAWO POWER CORE - Remote Control via Ember+

LAWO POWER CORE
539 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Core User Manual Version: 6.6.0/3 403/539
21. Networking Power Core
21.1 Remote Control via Ember+
Ember+ is a non-proprietary TCP/IP control protocol which allows devices to remotely control parameters within
Power Core, or Power Core to control parameters within an external device. It is supported by a wide range of
products and manufacturers. More details about the Ember+ protocol can be found at
https://github.com/Lawo/ember-plus/wiki.
Preparation & Configuration
All devices should be connected to the Lawo control network in the usual manner. You will need to know the
hostname or TCP/IP Address and Port Number of each Ember+ device on the network.
An Ember+ provider "publishes" parameters so that they may be controlled, or responded to, by an external
consuming device. Parameters which can be published from Power Core include source and summing bus
parameters, GPIO signals, matrix crosspoints, etc.
Power Core supports up to 5 Ember+ providers and 15 Ember+ consumers. This allows you to change what is
published to each external device, and how parameters are consumed.
For a guide to all of the Power Core parameter paths and values, please see the Ember+ Tree.
Note that VisTool MK2 is an Ember+ consumer which can control, or respond to, parameters published by
Power Core. For more information on VisTool's Ember+ capabilities, please refer to the "VisTool MK2 User
Guide".