5.2011.8583.0 C
6-2 Maintenance Procedures
Table 2. Maintenance during the year
Task months
Calibrate the additive dispenser(s) (frequency pulse)(Option) (see Calibrate the
Additives Dispenser (frequency pulse) on page 6-25)
1
Examine the mixer knives (see Examine the Mixer Knives on page 6-8)
1
Clean the jaws of the Feed Grabber (see procedure)
1
Clean the IPE profile of the Bridge Crane (see Clean the IPE profile of the Bridge Crane
on page 6-24)
4
Clean the control boxes (see Clean the Control Boxes on page 6-25)
6
Make sure an authorized person approves the Bridge Crane, Feed Grabber and the Lely
Vector stepladder yearly
12
6.2 Mixing and Feeding Robot
Unexpected movement of machine.
Risk of personal injury.
Always switch off the Mixing and Feeding Robot and remove the key before doing any
maintenance. After maintenance, make sure all covers are installed and properly fixed.
Do not put the Mixing and Feeding Robot into operation without the covers.
Do not lubricate the nipples on the ball bearings of the dosing roll and the feed door.
The Mixing and Feeding Robot has ball bearings on the dosing roll and the feed door
with lubrication nipples, but they must not be lubricated.
6.2.1 Clean and Inspect the Feed Loading Location
1. Clean the area near the feed loading position and charger.
2. When the Mixing and Feeding Robot is at the feed loading point, make sure the weight measurement
is not influenced and make sure:
1. The Mixing and Feeding Robot does not lean against any object.
2. No auger pipes, damaged fences, dugout or other objects lean on the Mixing and Feeding Robot.
3. Clean the floor and the strips that prevent the Mixing and Feeding Robot from rolling backwards out
of the charger.
in n o vato rs in agriculture