5.2011.8583.0 C
Maintenance Procedures 6-23
2. Make sure the grabber is still open for 60 – 65%.
3. Go to the page Testing > Test Lift Motor.
4. Push the button
UP to lift the grabber all the way up.
5. Put the Feed Grabber in operation (see procedure).
6. If present, put the Bridge Crane in operation (see procedure).
7. Switch on the Mixing and Feeding Robot with the Key (see procedure), if present switch on the second
Mixing and Feeding Robot.
6.4 General Feed Kitchen
6.4.1 Examine the Stock
1. Examine the stock of all the feed types, roughage, additives and concentrates.
2. If necessary:
1. Fill the feed kitchen (see Fill the Feed Kitchen on page 5-27).
2. Fill the additives dispenser (frequency pulse) (see Fill the Additives Dispenser (freq. pulse) on page
5-29).
3. Fill the concentrates silo (frequency weight).
6.4.2 Examine the Feeding
1. Examine the feed distributed at the feed fence and see if it is well mixed and cut.
If necessary examine the knives in the Mixing and Feeding Robot or adjust settings in T4C.
Ask Lely FMS for more advise about feeding.
2. Examine the feeding in the T4C reports.
If necessary adjust the settings in T4C for example:
• Proportions in a ration
• Scan interval
• In between and post mixing times
• Loading order
• Dosing weight
6.4.3 Clean the Drop Pipe of the Additives Dispenser(s) (freqency pulse)
Preparation
1. Connect the smartphone (see Connect the Smartphone to Device Software on page 5-15) to the Mixing
and Feeding Robot.
2. If necessary Manually drive (see Drive the Mixing and Feeding Robot Manually on page 5-34) the Mixing
and Feeding Robot away from the drop pipe.
in n o vato rs in agriculture