5-20 Operating Instructions
10. If an alarm goes ON at the additives dispenser (frequency pulse):
1. Make sure the bin is not empty and the transport pipe is not clogged up.
2. Connect the smartphone to the Feed Controller.
3. Go to the page Alarms > Active alarms.
4. Push the button
ACCEPT.
5. Test the additive dispenser (frequency pulse), go to the page Service > FreqCon Pulse >
Test FreqCon Pulse
1. Push
.
A window appears with the number of the dispenser.
2. Push the white box that displays the number, set the number and push OK.
3. Push
and .
A window appears with the weight.
4. Push the white box that displays the weight, set the weight and push OK.
5. Push
.
The set additive dispenser (frequency pulse) will operate and dose the set weight of the
additive.
Figure 45. Conventional dispenser
KEY: 3. Sensor -
Figure 46. Dispenser with stir motor
KEY: 5. sensor -
During operation check if the light of the sensor (3) (see figure 45 on page 5-20) or (5) (see
figure 46 on page 5-20) blinks with every pulse, if it is off the sensor is broken.
Check if the set weight is dispensed, if not, calibrate the additive dispenser (frequency pulse)
(see Calibrate the Additives Dispenser (frequency pulse) on page 6-25).
11. If necessary reset the MODalarm (see Reset alarms on the MODalarm on page 5-23) or the alarm on
CRS.
5.4.3 Restart the System after an Alarm
You can either use the WebUI or the smartphone to reset alarms on the Feed Controller software.
Restart the System with the WebUI
1. Start the WebUI (see page 5-16).