5.2011.8583.0 C
6-24 Maintenance Procedures
3. Switch off the Mixing and Feeding Robot with the key (see Switch off the Mixing and Feeding Robot
with the Key (MFR 2) on page 5-10).
4. If there are 2 Mixing and Feeding Robots, make sure the Mixing and Feeding Robot is not blocking the
return way of the other Mixing and Feeding Robot.
Clean
1. Use a stick to remove feed from the inside of the drop pipe (1) (see figure 32 on page 4-11) of the
additives dispenser(s) (frequency pulse).
Close-up
1. Switch on the Mixing and Feeding Robot with the key (see Switch on the Mixing and Feeding Robot
with the Key on page 5-14).
2. Manually drive and connect the Mixing and Feeding Robot to the charger (see Connect the Mixing and
Feeding Robot Manually to the Charger on page 5-35).
3. Put the Mixing and Feeding Robot in operation (see Put the Mixing and Feeding Robot In Operation on
page 5-2).
6.4.4 Clean the IPE profile of the Bridge Crane
Preparation
Unexpected movement of vehicle.
Risk of personal injury.
If no AGS settings are set, take the Mixing and Feeding Robot out of operation.
Use the Vector stepladder to do this procedure.
1. Take the Feed Kitchen out of Operation (see Put the Feed Kitchen in the Filling Mode with the Console
on page 5-3).
2. Put the Vector stepladder under the IPE profile.
Clean
1. Climb on the Vector stepladder.
2. Use a dry brush to clean the IPE profile.
3. Climb down and move the ladder to the next part of the IPE profile.
4. Repeat step 1 - 4 until both IPE profiles are clean.
Close-up
1. Remove the Vector stepladder from the feed kitchen.