5.2011.8583.0 C
Troubleshooting 7-3
5. Test the additive dispenser (frequency pulse), go to the page Service > FreqCon Pulse > Test
FreqCon Pulse
1. Push
.
A window appears with the number of the dispenser.
2. Push the white box that displays the number, set the number and push OK.
3. Push
and .
A window appears with the weight.
4. Push the white box that displays the weight, set the weight and push OK.
Be aware that feed falls from the feed pipe during the test.
5. Push
.
The set additive dispenser (frequency pulse) will operate and dose the set weight of the
additive.
During operation check if the light of the sensor blinks with every pulse, if it is OFF the
sensor is broken.
Check if the set weight is dispensed, if not calibrate the additive dispenser (frequency pulse)
(see Calibrate the Additives Dispenser (frequency pulse) on page 6-25).
If necessary reset the MOD alarm
1. If necessary reset the MODalarm (see Reset alarms on the MODalarm on page 5-23).
7.2 Troubleshooting Table
Explanation of the fields in the troubleshooting table:
Number of the alarm shown on the webpage and alarm message
A possible cause of the alarm Solution:
Preventive measure:
More information about the
cause of the alarm
Measures to take solve the alarm
and continue operation
General measure to take to
prevent this alarm in the future.
MFR = abbreviation of Mixing and Feeding Robot in the following tables.