Operating Instructions 5-23
5. Test the additive dispenser (frequency pulse), go to the page Service > FreqCon Pulse > Test
FreqCon Pulse
1. Push
.
A window appears with the number of the dispenser.
2. Push the white box that displays the number, set the number and push OK.
3. Push
and .
A window appears with the weight.
4. Push the white box that displays the weight, set the weight and push OK.
Be aware that feed falls from the feed pipe during the test.
5. Push
.
The set additive dispenser (frequency pulse) will operate and dose the set weight of the
additive.
During operation check if the light of the sensor blinks with every pulse, if it is OFF the
sensor is broken.
Check if the set weight is dispensed, if not calibrate the additive dispenser (frequency pulse)
(see Calibrate the Additives Dispenser (frequency pulse) on page 6-25).
If necessary reset the MOD alarm
1. If necessary reset the MODalarm (see Reset alarms on the MODalarm on page 5-23).
5.4.4 Reset alarms on the MODalarm
The MODalarms can be reset on the smartphone in the feed controller (PDB) in the (Lely Control app) or
on the connected Horizon PC.
Reset the MODalarm on the smartphone in the feed controller
1. Open the Lely Control app on the smartphone and connect to the feed controller (PDB).
2. Go to the page Alarms > Reset ModAlarm.
3. Push the button
RESET, to reset the MODalarm.
Reset the MODalarm on the Horizon PC
Do this procedure on the Horizon PC or on a PC connected to the farms network that is
connected to the MODalarm of the Vector.
1. On the web browser go to the page: http://10.4.1.210