5.2011.8583.0 C
2-26 Safety
2.4.3.6 Safety Fence
Sensors in the tensioner pole of the safety fence detect if the fence is closed and at the correct tension. If
the tension is lost the Feed Grabber and Bridge Crane immediately stop operation. Be aware that the MFR
will not stop operation. To reset the sensor, close the safety fence and turn the winch until the light goes
off.
When the light is on, it indicates an unsafe situation. When the light is off it indicates that the fence is at
the correct tension.
2.4.3.7 Safety Switch on Kitchen Fill Door
Risk of accident caused by a malfunctioning safety switch.
Serious injury or death.
Do not tamper with the safety switch.
On the kitchen fill door an access control switch is installed.
When the kitchen fill door is opened unauthorized, the control switch switches and the Feed Grabber,
Bridge Crane and safety fence immediately stop operation.
Be aware that the Mixing and Feeding Robot will not stop operation.
To reset the access control switch, close the kitchen fill door and put the feed kitchen into operation.
2.5 Safety Zones
2.5.1 General Safety Zones
The Vector type plate attached on the power distribution box indicates the risk zones on the farm.