5.2011.8583.0 C
4-12 Description
Additives Dispenser with Stir Motor (frequency pulse)
Figure 33. Dispenser with Stir Motor
KEY: 1. Drop pipe - 2. Dispenser silo - 3. Auger motor - 4. Stir motor - 5. Sensor pulse counter
A control box with two or more frequency regulators is installed in the feed kitchen. One frequency
regulator for the auger motor and one for the stir motor.
The frequency regulator regulates the number of pulses of the motor of the additives dispenser.
The dispenser doses per pulse, in the software this is called FreqCon Pulse.
4.2.9 External Concentrates (frequency weight)
A control box with one or more frequency regulators (one for each concentrate) regulates the on/off
signal for distribution of the concentrate. This signal switches to Off when the Mixing and Feeding Robot
has measured the set weight. The runtime is protected by a maximum runtime, this is the expected
runtime plus 30%.
The Mixing and Feeding Robot weighs the concentrates during loading. In the software this is called
FreqCon Weight.