6.2.2 Clean the Dosing Roll and Position Sensor
Preparation
1. Switch off the Mixing and Feeding Robot with the key and remove the key (see Switch off the Mixing
and Feeding Robot with the Key (MFR 2) on page 5-10).
2. Remove the bolt (1) and open the maintenance door (2) (see figure 53 on page 6-3).
Figure 53. Open the maintenance door
KEY: 1. Bolt - 2. Maintenance door
Clean
1. Carefully remove all feed remains from the dosing roll (3) (see figure 54 on page 6-4).
2. Remove all dirt and fibers between the position sensor (1) and the metal arm (2) on the dosing roll.
3. Remove all dirt in the top area and between the motors.
4. Every two or three months use compressed air to blow all dirt from the motor of the dosing roll and
the motor of the feed door.