Maintenance Procedures 6-25
2. Put the feed kitchen in operation (see Put the Feed Kitchen in Operation on page 5-1).
6.4.5 Clean the Control Boxes
To prevent corrosion all control boxes that are covered by or have contact with minerals
and concentrates must be cleaned regularly.
Clean the master and slave control box of the Bridge Crane during the procedure Clean
the IPE profile (see Clean the IPE profile of the Bridge Crane on page 6-24) and use the
Lely step ladder.
1. Use a wet cloth to clean all control boxes in the green and yellow zone.
6.4.6 Calibrate the Additives Dispenser (frequency pulse)
Calibrate the additives dispenser (frequency pulse):
• When you start with a new type of additive.
• After the weather or humidity has changed.
• When you notice a change in the coarseness of a new badge.
• Once a month.
Tools
1. Bucket for 3 to 6 kg (6.6 to 13 lb).
2. Scale with an accuracy in grams.
Preparation
1. Take the Feed Kitchen out of Operation (see Put the Feed Kitchen in the Filling Mode with the Console
on page 5-3).
2. To make sure the Mixing and Feeding Robot does not return during calibration, switch off the Mixing
and Feeding Robot with the key (see Switch off the Mixing and Feeding Robot with the Key (MFR 2) on
page 5-10).
Calibrate
1. Make sure the transport pipe with the spring auger is completely filled with the additive. If necessary
fill the transport pipe (see Fill the Additives Dispenser (freq. pulse) on page 5-29).
2. Hold a clean bucket under the drop pipe.
3. Connect the smartphone to the Feed Controller.
4. Go to the page Service > FreqCon Pulse >Test FreqCon Pulse.