5.2011.8583.0 C
5-22 Operating Instructions
4. If the Mixing and Feeding Robot gives the alarm that the automatic (barn) door is in error state:
1. Close the door if it was opened
2. Open the door if it was closed
3. If this does not work, reboot the system by switching the power OFF for a few seconds and
ON again.
5. Start the Lely control app and connect the smartphone (see Connect the Smartphone to Device
Software on page 5-15) to the Mixing and Feeding Robot.
6. Push
to confirm the alarm message.
7. Test the operation of the automatic (barn) door when operated from the Mixing and feeding Robot as
follows:
1. Manually drive the Mixing and Feeding Robot to the automatic door until it is within
Bluetooth range.
2. Go to the page Test > Auto. door.
3. Push the button
to open the door, or to close the door.
If this does not work you can test if it is possible to open and close the door with the barn
door software:
Connect the smartphone (see Connect the Smartphone to Device Software on page 5-15) to the
Automatic (barn) door.
4. Go to the page Testing.
5. Push the button Open or Close.
6. If this does not work ask your Lely service technician for advice.
If the alarm is on the additives dispenser (frequency pulse)
1. Make sure the bin is not empty and the transport pipe is not clogged up.
2. Connect the smartphone to the Feed Controller.
3. Go to the page Alarms > Active alarms.
4. Push the button
ACCEPT.