5.2011.8583.0 C
Troubleshooting 7-9
3DBC No initial Feed Flow was detected
See alarm 3CCC Solution:
Preventive measure:
This is the non critical version of
alarm 3CCC, so the MFR will have
continued without this feed
type, problems and solutions are
similar.
3C76 No mains power during feed loading
No mains available on the MFR
when it is loading feed (mixing)
Solution:
Preventive measure:
When a task is started and
during the loading of the feed
the MFR checks if there is main
power available to turn the
mixer. When no power is
detected, this can be caused by:
• Power is present at the
charge pole, but not in the
MFR
• No power on the charge pole
Check if MFR is properly engaged
with the charge pole, reconnect
if necessary.
Check if power is reaching the
charge pole and if the circuit
breaker of the charger in the
Power Distribution Box is still on,
the kitchen relay needs to be
activated for this (if it is not, the
white light in the play button on
the kitchen console will be on or
blink).
Ask your Lely center to check if
the connectors on the charge
pole and/or on the MFR are
worn.
When the MFR often looses
connection during loading of
feed, check the condition of the
plastic strip on the floor, this
prevents the MFR from rolling
back. Also a pile of feed built up
under the wheels can make the
plastic strip useless. Regularly
clean this area.
3C03 No reset point detected (R <P1> A <P2>)
MFR already past the reset strip
before it starts looking for it
Solution:
Preventive measure:
The MFR will only search for
reset points in the last part of
the route action. If the action
has been started in the wrong
position or the wheel diameter is
set incorrect, the MFR may have
travelled further already than it
assumes.
If route actions have been
changed recently all related
actions may not have been
adjusted.
Reverse the MFR manually to a
point just before the reset strip
and resume the route.
Ask your Lely Center to adjust
(increase) the wheel diameter
when the MFR always looks too
late for the reset points. When it
only looks too late on one action
reduce the length of that route
action.
Beware: Always write down the
initial values before you make
changes.
in n o vato rs in agriculture