7-16 Troubleshooting
3C86 Barn door <P1> is unable to open
Communication network
problem
Solution:
Preventive measure:
The Bluetooth communication of
the door has an error, therefore
the MFR is not able to open the
door. Manually open and close
the door with the button to see
if the door functions well.
Connect the Lely Control app
with the door to see if it is
possible to open the door via the
MFR. If this is not possible the
communication is the problem.
Position the Bluetooth antenna
in such a way that there is a
good connection from both sides
of the barn door or ask the Lely
Center to position the antenna.
Communication problem control
box of the door
Solution:
Preventive measure:
Connect the Lely Control app
with the door to see if it is
possible to open the door
directly. If a connection can not
be made the control box of the
door could have a software
malfunction.
Restart the complete door
control box by switching the
main power switch to off and
switch it on again. After a few
minutes the communication
comes online again.
Power loss control box of the
door
Solution:
Preventive measure:
The barn door cannot be
controlled by the control box
because there is no power on
the box.
Check the fuse in the main power
box of the farm. The control box
of the barn has a different power
connection than the Vector
system.
Communication problem MFR Solution:
Preventive measure:
The Bluetooth communication
part of the MFR has an error and
can therefore not communicate
with the Bluetooth module of
the door. Connect the lely
control app with the MFR to see
if it is possible to open the barn
door via the MFR.
Take the MFR out and in
operation again to trigger the
communication.
Restart the MFR with the key
switch, be aware that the current
route and information will be
lost.
Check the MFR communication
by opening the barn door. Drive
back to the charger and start a
manual route for the just
interrupted feeding task.