Loading...
236F00C4
SensorType:Watchdog
2EventSeverity:Info
Description:TimeExpired
-Asserted
Thewatchdogtimer
isexpired.
Itisjustaninformation.Usersdon'tneedto
doanything.
236F01C4
SensorType:Watchdog
2EventSeverity:Info
Description:HardReset-
Asserted
TheHardReset
istriggeredby
watchdog.
Itisjustaninformation.Usersdon'tneedto
doanything.
236F02C4
SensorType:Watchdog
2EventSeverity:Info
Description:PowerDown
-Asserted
ThePowerDown
istriggerredby
watchdog.
Itisjustaninformation.Usersdon'tneedto
doanything.
236F03C4
IPMI_Watchdog
SensorType:Watchdog
2EventSeverity:Info
Description:PowerCycle
-Asserted
ThePowerCycle
istriggeredby
watchdog.
Itisjustaninformation.Usersdon'tneedto
doanything.
076F01C5
076F01C6
CPU%_Status(%=
CPUnumber)
SensorType:Processor
EventSeverity:Critical
Description:ThermalTrip
-Asserted
CPUtemperature
istoohigh.Atthe
sametime,system
willbeshutdown.
1.CheckcontactconditionofCPUheat
sink.2.ChecktheLenovosupportwebsite
foranapplicabletiporfirmwareupdatethat
appliestothiserror.3.CheckFanstatus.if
Fanisbroken,pleasereplacethenewFan.4.
ContactyourLenovoservicerepresentative
forsupport
070301C7SensorType:Processor
EventSeverity:Warning
Description:State
Asserted-Asserted
CPUbeginsto
throttlebecauseits
temperatureistoo
high.
1.CheckcontactconditionofCPUheat
sink.2.ChecktheLenovosupportwebsite
foranapplicabletiporfirmwareupdatethat
appliestothiserror.3.CheckFanstatus.if
Fanisbroken,pleasereplacethenewFan.4.
ContactyourLenovoservicerepresentative
forsupport
076F0AC7
PROC_Hot
SensorType:Processor
EventSeverity:Warning
Description:Processor
AutomaticallyThrottled-
Asserted
CPUbeginsto
throttlewhichis
triggeredbyPSU
alert.
1.CheckcontactconditionofCPUheat
sink.2.ChecktheLenovosupportwebsite
foranapplicabletiporfirmwareupdatethat
appliestothiserror.3.CheckFanstatus.if
Fanisbroken,pleasereplacethenewFan.4.
ContactyourLenovoservicerepresentative
forsupport
CF6F00C9Chassis_Control
SensorType:Customer
SensorTypeEvent
Severity:InfoDescription:
ChassisControl-
Asserted
BMCgets"Chassis
Control"command.
Itisjustaninformation.Usersdon'tneedto
doanything.
070301D0
CPU_CATERR
SensorType:Processor
EventSeverity:Critical
Description:State
Asserted-Asserted
Catastrophicerror
happened.
1.ChecktheLenovosupportwebsitefor
anapplicabletiporfirmwareupdatethat
appliestothiserror.2.Restarttheserver.3.
ContactyourLenovoservicerepresentative
forsupport
070301D1
CPU_VR_Fault
SensorType:Processor
EventSeverity:Critical
Description:State
Asserted-Asserted
CPUVRfault.
1.ChecktheLenovosupportwebsitefor
anapplicabletiporfirmwareupdatethat
appliestothiserror.2.Restarttheserver.3.
ContactyourLenovoservicerepresentative
forsupport
164LenovoThinkServersd350ServerType5493,LenovoThinkServern400EnclosureType5495InstallationandServiceGuide