0C0301D2
Mem_Therm_Trip
SensorType:Memory
EventSeverity:Critical
Description:State
Asserted-Asserted
Memory
temperatureistoo
high.Atthesame
time,systemwillbe
shutdown.
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.CheckFanstatus.ifFan
isbroken,pleasereplacethenewFan.3.
ContactyourLenovoservicerepresentative
forsupport
196F01D3
PCH_Therm_TripSensorType:Chipset
EventSeverity:Critical
Description:State
Asserted-Asserted
PCHtemperature
istoohigh.Atthe
sametime,system
willbeshutdown.
1.CheckcontactconditionofPCHheat
sink.2.ChecktheLenovosupportwebsite
foranapplicabletiporfirmwareupdatethat
appliestothiserror.3.CheckFanstatus.if
Fanisbroken,pleasereplacethenewFan.4.
ContactyourLenovoservicerepresentative
forsupport
0D6F01D4
HDD_Status
SensorType:DriveSlot
(Bay)EventSeverity:
CriticalDescription:Drive
%Fault-Asserted
HDD%fault.(%=
HDDnumber)
1.CheckLenovosupportsiteforan
applicableservicebulletinorfirmwareupdate
thatappliestothiserror.2.ReplaceHDD.3.
ContactyourLenovoservicerepresentative
forsupport.
1D6F02E0
BIOS_Boot_up
SensorType:System
Boot/RestartInitiated
EventSeverity:Info
Description:InitiatedBy
WarmReset-Asserted
BIOSbootupand
it'sinitiatedby
warmreset.
Itisjustaninformation.Usersdon'tneedto
doanything.
0C6F00E2
SensorType:Memory
EventSeverity:Critical
Description:Correctable
ECC-Asserted
Asinglebiterror
isoccurredIn
memory.Thiserror
willberepaired
automatically.
1.Ifthenodehasrecentlybeeninstalled,
moved,serviced,orupgraded,verifythatthe
DIMMisproperlyseatedandvisuallyverify
thatthereisnoforeignmaterialinanyDIMM
connectoronthatmemorychannel.Ifeither
oftheseconditionsisfound,correctandretry
withthesameDIMM2.Ifproblemre-occurs
onthesameDIMMconnector,swapthe
otherDIMMsonthesamememorychannel
acrosschannelsoneatatimetoadifferent
memorychannelorProcessor.(checkservice
informationforthisproduct/Installguidefor
populationrequirementsforsparing/paring
modes).IfproblemfollowsamovedDIMM
toadifferentmemorychannel,replacethat
DIMM.
0C6F01E2
SensorType:Memory
EventSeverity:
CriticalDescription:
UncorrectableECC-
Asserted
Amultiplebits
errorisoccurredin
memory.Thiserror
willcausesystem
tobehangup.
1.ChecktheLenovosupportwebsitefor
anapplicableservicebulletinorfirmware
updatethatappliestothismemoryerror.
2.Ifthenodehasrecentlybeeninstalled,
moved,serviced,orupgraded,verifythatthe
DIMMisproperlyseatedandvisuallyverify
thatthereisnoforeignmaterialinanyDIMM
connectoronthatmemorychannel.Ifeither
oftheseconditionsisfound,correctand
retrywiththesameDIMM.3.Ifnoproblem
isobservedontheDIMMconnectorsand
theproblempersists,replacetheDIMM
identifiedbyLightPathand/oreventlog
entry.4.Ifproblemre-occursonthesame
DIMMconnector,swaptheotherDIMMson
thesamememorychannelacrosschannels
oneatatimetoadifferentmemorychannel
orProcessor.(checkserviceinformation
forthisproduct/Installguideforpopulation
Memory_Status