Figure 328. Front backplane cable routing
Figure 329. Rear backplane cable routing
From To From To
1 Backplane 1: SAS
1 16i adapter
Gen 4: C0
Gen 3: C0C1
1 Backplane 4: SAS 1 8i adapter: C0
2 Backplane 2: SAS
2 16i adapter
Gen 4: C1
Gen 3: C2C3
2 Backplane 4: PWR
2 Onboard: 7mm power
connector
Front + middle backplanes: 16 x 2.5" SAS/SATA + 4 x 2.5"/8 x 2.5" SAS/SATA
This topic provides cable routing information for the server model with two 8 x 2.5-inch SAS/SATA front
backplanes and one or two 4 x 2.5-inch SAS/SATA middle backplanes.
“16 x 2.5" SAS/SATA + 4 x 2.5" SAS/SATA” on page 335
“16 x 2.5" SAS/SATA + 8 x 2.5" SAS/SATA” on page 336
16 x 2.5" SAS/SATA + 4 x 2.5" SAS/SATA
The following shows the cable connections for the front 16 x 2.5-inch SAS/SATA + middle 4 x 2.5-inch SAS/
SATA configuration with one 16i RAID/HBA adapter and one 8i RAID/HBA adapter.
To connect riser 3 and riser 4 cables, see
“Riser 3/4 cage” on page 306.
To connect riser 5 cables, see
“Riser 5 cage” on page 309.
To connect cables to the front and rear OCP interposer cards, see
“OCP interposer cards” on page 297.
Connections between connectors:
1 1 , 2 2 , 3 3 , ... n n
Chapter 6
. Internal cable routing 335