11-3
RLC-4 V1.79 Copyright © 1998 Link Communications Inc. 9/18/98
085: Enable/Disable IDing a Port
This command allows you to enable or disable the IDing functions for a port. Normally all ports are
IDed, including link ports. Often this is not desired. This command allows you to turn off the
IDing functions.
<085> p c
Parameters:
- 085 is the default command name.
- P is the port for which to enable or disable the ID's (1..4)
- C is 1 to enable ID's, 0 to disable them
Defaults:
IDs are enabled only on port 1.
Notes:
If you only want to disable some of the ID's for a port, keeping the pending ID's but not the
initial ID, for example, just delete the ID macro that you don't want to do anything (see Chapter 8
for macro definitions). If you do this, the controller may not satisfy identifying requirements.
086: Recall Which Ports have ID's Enabled
This command lists the ports that have IDing enabled. If all ports do, it sends "1234".
<086>
Parameters:
- 086 is the default command name.