2-6
RLC-4 V1.79 Copyright © 1998 Link Communications Inc. 9/18/98
003,004: Recall a Port's Connections
This command allows you to find out where port X's receiver or transmitter is connected.
<003> x Interrogate a Receiver
<004> x Interrogate a Transmitter
Parameters:
- 003 is the default command name. This command finds what transmitters are connected
to receiver 'X'.
- X is the receiver to recall the connections to
- 004 is the default command name. This command finds what receivers are connected to
transmitter 'X'.
- X is the transmitter to recall the connections to
Default:
- All port default as links
Example 1:
Port 1 is connected to ports 2 4
<003> 1 <unkey>
Response:
CW Response "1 C 2 4"
Example 2:
Ports 1,3, are connected to port 2
<004> 2 <unkey>
Response:
CW response "2 C 1 3"