13-11
RLC-4 V1.79 Copyright © 1998 Link Communications Inc. 9/18/98
119: Set Allowed Numbers Table Slot
This command allows you to set one of the slots in the allowed numbers table. For a description of
this table and how to use it, see the explanation of the dialing tables before Command 110.
<119> ss Clear slot ss
<119> ss d..d Program slot ss
Parameters:
- 119 is the default command name.
- SS is the slot number (00..19). Must be two digits.
- D..D is the area code/prefix (do not include the last four digits of the phone number). The
'#' digit is a wildcard that matches any digit.
120: Recall Allowed Numbers Table Slot
This command allows you to recall the contents of one of the slots in the allowed numbers table.
For a description of this table and how to use it, see the explaination of the dialing tables before
Command 110.
<120> ss
Parameters:
- 120 is the default command name.
- SS is the slot number (0..19)