6-10
RLC-4 V1.79 Copyright © 1998 Link Communications Inc. 9/18/98
044: Set Up DTMF Regenerate Parameters:
This command allows you to set up the DTMF regenerate parameters for port 4 (the only port that
can generate DTMF). You may need to use this command to slow your DTMF tones down if a
scanning DTMF decoder is on any of the attached systems that you want the RLC-4 to control.
<044> aaaa bbbb
Parameters:
- 044 is the default command name.
- AAAA is the length of the DTMF sequence in 10mS steps (0000..9999)
- BBBB is the pause between DTMF digits in 10mS steps (0000..9999)
Default:
Both length and pause set to 100mS lengths (aaaa = 010)
CW Response:
AAAA <pause> BBBB