16-2
RLC-4 V1.79 Copyright © 1998 Link Communications Inc. 9/18/98
038: Kill All Responses Following This Command
This command kills all CW responses beyond this point. This command designed for use within a
macro. When multiple commands are executed inside a macro, the commands that are executed
contain their own message responses. To keep from hearing all of the responses when the macro is
executed, simply execute command 038 first, then all messages following that command are
canceled. If you want a message response to occur from within a macro, send the response before
you execute 038.
<038>
Parameters:
- 038 is the default command name.
Notes:
The changes made to the audio routing variable by this command affect all commands
(including other macros) executed until the end of the macro containing this command, or until
command 037 or 038 are executed again, whichever occurs first.
Example:
Want to read the change the access mode of port 1 and speak a message indicating what you did.
1) Use a multiple command macro for this purpose
Command 165 will be used to execute this sequence (Macro 165)
2) 005 is the Access mode change command
Want to change the mode to COR and PL Access
005 1 2 "Port 1 COR and PL"
3) 030 is the CW send command
Want to send "R PL"
4) Macro programming:
055 165 ; erase the macro
056 165 030 27 40 25 21 ; send "R PL"
056 165 038 ; be quiet for rest of macro
056 165 005 1 2 ; set to PL access mode
5) The macro will send the CW message "R PL" and not the mode change message "1 2"

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Link Communications RLC-4 and is the answer not in the manual?

Link Communications RLC-4 Specifications

General IconGeneral
BrandLink Communications
ModelRLC-4
CategoryController
LanguageEnglish

Related product manuals