2-4
RLC-4 V1.79 Copyright © 1998 Link Communications Inc. 9/18/98
001: Monitor one Port from another Port
This command allows you to monitor one radio port from another radio port.
<001> x y
Parameters:
- 001 is the default command name
- X is the doing the monitoring of port Y
- Y is the port being monitored
Default:
- All port default as links
Note:
If you want a two-way connection, where port A can monitor port B and port B can
monitor port A, use command 000.
Example:
Monitor Port 4 by Port 1
<001> 1 4 <unkey>
Response:
CW response "1 M 4"