1-4
RLC-4 V1.79 Copyright © 1998 Link Communications Inc. 9/18/98
squelch the audio and present it on J1.
Receiver Port Adjustment:
- Connect the receiver port that is receiving a signal to all connected transmitter ports.
Transmitter Port Adjustment:
- Present a stable Tone or DTMF tone to the receiver that you are adjusting.
- Adjust the 'RX' pot so that the signal on J1 is 1 volt peak-to-peak for the active receiver
- Adjust the 'TX' pots on all other connected transmitters to obtain the desired deviation.
- Your transmitters should not need any additional adjustments once one receiver is set up.
Follow the above adjustment steps for all other connected receivers
Tone Generator Adjustment:
- Generate a tone test sequence using RLC-4 using command 040
- Adjust "TN" pot on the RLC-4 to the desired deviation
- 1.5Khz deviation is typical