EasyManua.ls Logo

Lucent Technologies MERLIN LEGEND Release 6.1 - Replacing a Module

Lucent Technologies MERLIN LEGEND Release 6.1
355 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Installing the Control Unit
Page 2-41
Replacing a Module
Replacing a Module
!
CAUTION:
This section does not apply to the processor or power supply.
Although the system allows you to remove and replace modules without
affecting call processing, partially inserting and removing a module can
cause a cold start.
To add a 100D module or change any of its DS1 parameters, the system
must be idle.
When you replace a module, use the same module type. For example, do
not put an 008 MLX module in place of a 400 GS/LS/TTR module. If a
module is replaced with another type of module, or if a module is added to
the system without powering down the system first, a cold start (System
Reset) occurs.
If you move any module to a different slot, be sure to renumber the
modules by selecting
%PBSE5FOVNCFS
from system programming. See
System Programming
for information about board renumbering.
NOTE:
You can remove and replace line/trunk and extension modules with the
system power on, without affecting normal call processing.

Table of Contents