MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Connecting the Control Unit to the Network Interface
Page 4-11
Wiring
Figure 4-5. RJ11 and RJ14 Interfaces
!
CAUTION:
Incorrect wiring can damage the ports and cause them to stop
functioning. Make sure you use the proper cords. For all GS/LS
modules, do the following:
â– 
Use a D2R cable from an RJ11.
â– 
Do not use the Brand-Rex Quad cable from an E66 block.
â– 
If you cannot avoid using the Brand-Rex Quad cable,
reverse the tip and ring leads at the E66 block to correct
the mismatch.
To connect the RJ11 and RJ14 network interfaces to the control unit,
follow the steps below:
Single-Line Adapter (RJ11)
2-Line Adapter (RJ14)