IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
5-65
C Lower Lmt 1 N/C Lower Limit–SLOW DOWN;
Normally Closed
5-20
D Lower Limit 2 N/C Lower Limit–STOP; Normally
Closed
5-20
E M-Speed Gain 1 Micro-Positioning Control
Multiplier 1
5-19
F Not used No function n/a
10 M-Speed Gain 2 Micro-Positioning Control
Multliplier 2
5-19
11 Load Float 1 Load Float Hold; when input
during run, Load Float will
remain on.
n/a
12 Weight Lmt N.C. Upper Limit - Stop by C3-08,
normally closed
n/a
13 Ultra/Swift Lift Ultra-Lift enable 5-26
14 Alt T-Lim Gain Alternate Torque Limit
Multiplier
5-28
15 Forward Jog Jog Control FORWARD
command
5-3
16 Reverse Jog Jog Control REVERSE
command
5-3
17 Forward Inch Inch Control 5-42
18 Reverse Inch Inch Control 5-42
19 Inch Repeat Inch Control 5-42
1A Acc/Dec 2 Acceleration and Deceleration
Changeover 2 Time
5-12
1B Acc/Dec 3 Acceleration and Deceleration
Changeover 3 Time
5-13
1C Acc/Dec 4 Acceleration and Deceleration
Changeover 4 Time
5-13
1D Digital Chngover Analog/Digital Reference
Changeover B1-18=1
Open=Analog
Closed=Digital Reference from
B1-01 Only
5-13
1F Opt/Inv Switch Frequency Reference from
Option Card = Closed
n/a
20 thru 2F External Fault See “External Fault response
selection”
5-72
30 Program Lockout Program Lockout n/a1
31 Local/Remote Sw Closed = Local n/a
32 Ext BB N.O. Immediate Stop at STOP
Command; Normally Open
n/a
33 Ext BB N.C. Immediate Stop at STOP
Command; Normally Closed
n/a
34 Spd/Trq Chngover Speed- and Torque-Control
Changeover
n/a
35 Load Float 2 Initiates Zero Servo Sequence
Timed by C4-01 Timer
5-23
36 Polarity Rev Reverse Polarity in Torque
Control
n/a
37 ASR Gain Switch Automatic Speed Regulator
Multiplier Changeover
n/a
38 Speed Hold 1 Frequency out is held n/a
Parameter
Code Display Function
Ref Page
Number