OPERATING PROCEDURES TMS9000-2 OPERATOR MANUAL
4-66
Published 02-21-2019, Control # 611-05
- Locking the telescoping cylinder, refer to Lock
telescoping cylinder, page 4-68
- Unlocking the telescopic section, refer to Unlocking
the telescopic section, page 4-68
- Telescoping the telescopic section, refer to
Telescoping the telescopic section, page 4-69
- Locking the telescopic section, refer to Locking the
telescopic section, page 4-70
NOTE: The operating order depends on the current initial
position. For an overview of a telescoping process
(example), refer to Telescoping process, page 4-
61.
NOTE: The lengths given in the following illustrations are
purely sample values, and may differ from the
current display.
Checking the initial position
Before telescoping, you must check the following statuses:
- the current telescope status,
- the position of the telescoping cylinder,
- the position of the locking pins.
To do so, open the main menu and press the button (1,
Figure 4-121) or (2) once.
Open the Manual telescoping menu (1, Figure 4-122).
Current telescoping
The display (1, Figure 4-123) shows how far the telescoping
cylinder is extended, e.g. 0%.
The display (2) shows the current main boom length.
The display (3) shows the corresponding telescopic section,
e.g. telescopic section 1.
Position of the telescoping cylinder
The display (1, Figure 4-123) shows how far the telescoping
cylinder is extended, e.g. 0%.
If the telescoping cylinder is near a locking point:
- The display (3) shows the corresponding telescopic
section, e.g. telescopic section 1.
- The display (4) shows one or two arrows, depending
on the distance to the locking point.
Position of the locking pins
The current positions of the locking pins are (Figure 4-124):
The area (3) shows an enlarged cut-out.
The current settings are shown in different colors.
8849-45
FIGURE 4-121
8882-2
FIGURE 4-122
1
1 on the telescopic section
2 on the telescoping cylinder
Red: Unlocked
Green: Locked
Yellow: Intermediate position
8882-7a
FIGURE 4-123
1
2
3
4