Beschreibung der einzelnen Menüpunkte
4-13
HOST CHANNEL
The following types are available:
– PARALLEL ONLY (Default)
– I/O EXTENSION
The selection PARALLEL ONLY means that only the Centronics port can receive
data.
If I/O EXTENSION is selected only the optional channel can be used e.g. Ethernet.
RECAL FACTORY
By calling up RECALL FACTORY in CONFIG. MENU all menus, including all
profiles are reset to the factory defaults. This function needs to be confirmed by the
additional prompting YES / NO to prevent unintended reset of all parameters.
Note: The printer needs up to two minutes for reset!
RESET TRU INFO
After the exchange, the Transfer Roller Unit (see also Chapter 5), the counter
must be reset. By selecting YES, the zero position of the counter is reached.
EXCHANGE TRU
Select the parameter YES to move the TRU forward. This facilitates the removal
and installation of TRU. By the choice of parameter NO the TRU is pushed back
into the working position. However, if the TRU has not been pushed back over the
menu in the working position, this is carried out automatically before the next print
job.
After changing the TRU, the counter must be reset by RESET INFO TRU (see
above).
4.3.2 CLOCK MENU
Following settings are possible:
WEEKDAY
DAY
MONTH
YEAR
HOUR
MINUTE
SECOND