QX-830 Compact Industrial Scanner User’s Manual A-29
Appendices
Read Cycle
Trigger Mode / Filter Duration
Trigger Mode
Leading Edge Trigger Filter
Trailing Edge Trigger Filter
Trigger Mode / Trigger Filter Duration
<K200,trigger mode,leading edge trigger filter duration,trailing
edge trigger filter duration>
Serial Trigger Character <K201,serial trigger character>
External Trigger State <K202,external trigger state>
End of Read Cycle <K220,mode,read cycle timeout>
Decodes Before Output <K221,mode,number before output>
Multisymbol <K222,number of symbols,multisymbol separator>
Serial Trigger Start Character <K229,start character>
Serial Trigger Stop Character <K230,stop character>
Processing Timeout <K245,processing timeout>
Scan Speed <K500,scan speed>
Maximum Element <K502,maximum element>
Automatic Gain Control
<K504,gain level,AGC sampling mode,AGC minimum,AGC
maximum>
Symbol Detect Status / Transition
Counter
<K505,symbol detect status,transition counter>
Scan Width Enhance <K511,status>
AGC Tracking <K520,tracking>
Laser Setup
<K700,laser on/off,laser framing status,laser on position,laser off
position,laser power>
Serial Cmd: <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default: 0 = Continuous Read
Options: 0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and Edge
Serial Cmd: <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default: 313 (~10 ms)
Options: 1 to 65535 (x 32.0 µs)
Serial Cmd: <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default: 313 (~10 ms)
Options: 1 to 65535 (x 32.0 µs)