A-30 QX-830 Compact Industrial Scanner User’s Manual
Serial Commands
Serial Trigger Character (Delimited)
External Trigger State
End of Read Cycle
End of Read Cycle Mode
Read Cycle Timeout
Decodes Before Output
Decodes Before Output
Mode
Multisymbol
Number of Symbols
Serial Cmd: <K201,serial trigger character>
Default: Space (0x20)
Options: Any 7-bit ASCII character
Serial Cmd: <K202,active state>
Default: 1 = Positive
Options: 0 = Negative 1 = Positive
Serial Cmd: <K220,end of read cycle,read cycle timeout>
Default: 0 = Timeout
Options: 0 = Timeout
1 = New Trigger
2 = Timeout or New Trigger
3 = Last Frame
4 = Last Frame or New Trigger
Serial Cmd: <K220,end of read cycle,read cycle timeout>
Default: 100 (x10 ms = 1 second)
Options: 1 to 65535
Serial Cmd: <K221,decodes before output,mode>
Default: 1
Options: 1 to 255
Serial Cmd: <K221,decodes before output,mode>
Default: 0 = Non-Consecutive
Options: 0 = Non-Consecutive 1 = Consecutive
Serial Cmd: <K222,number of symbols,multisymbol separator>
Default: 1
Options: 1 to 100