EasyManua.ls Logo

MIMAKI UCJV300-75 - Reset the Set Value; Eliminate Ink over Flow

MIMAKI UCJV300-75
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-14
Chapter 5 Maintenance
Reset the set value
1
Press the
(MENU)
and
press the key.
MAINTENANCE MENU will be displayed.
2
Press to select "NOZZLE
RECOVERY", and press the key.
3
Press to select "RESET", and
press the key.
4
Press and
(<<)
(>>)
to select the Nozzle line that needs to be
reset, and press the key.
A reset confirmation message will be displayed.
5
and press the key.
6
Press the key several times to
end the setting.
Eliminate Ink Over
Flow
1
Press
(MENU)
in LOCAL.
2
Press to select
“MAINTENANCE”, and press the
key.
MAINTENANCE MENU will be displayed.
3
Press
(<<).
4
Press to select “OVER
MAINTENANCE”, and press the
key.
5
Press to select a head.
6
Press the key.
7
Press the key several times
to end the setting.
If the problem is not eliminated after performing
this operation once, repeat the operation.
If the problem is not eliminated after performing
the operation three times, contact our service desk
or your local distributor for service.