Chapter 5 Settings
112
LT Mode
LT mode is enabled under the following conditions:
Ink type Ink set Resolution Number of passes Media
LUS170 4-color 300 × 900 6 passes PVC
Tarpaulin
600 × 600 8 passes PVC
Tarpaulin
6-color 300 × 900 12 passes PVC
Tarpaulin
600 × 600 16 passes PVC
Tarpaulin
Changing the name of a setting type
You can change the name of a setting type. The name can include alphanumeric characters or symbols.
1
In LOCAL mode, select [MENU] > [Setup], then press the [ENTER] key.
• The setting types are displayed.
2
Select Settings 1 to 4 and press the [FUNC2] key.
• The rename screen appears.
3
Enter the desired name, then press the [ENTER] key.
• The setting type is renamed.