Chapter 7 Troubleshooting
180
Error
number
Message Cause Corrective action
B0A CTC PCB Vpow
• A problem was detected with
the CTC PCB power supply
voltage.
• Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 34)
B0B CTC PCB V24
B0C CTC PCB V5R0
B0D CTC PCB V3R3
B0E CTC PCB V2R5
B0F DIO PCB Uvpow
• A problem was detected with
the UV-DRV PCB power
supply voltage.
• Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 34)
B19 Station4 PCB V36
• A problem was detected with
the station IV PCB power
supply.
SYSTEM HALT
Message Corrective action
SYSTEM HALT(*)
000: Message
• Turn off the power on the machine and turn it on after a while.
"Turning Off the Power"(P. 34)
SYSTEM HALT(*)
406 : WIPER ORG
1. Clean the wiper and around the wiper.
"Wiper Cleaning"(P. 132)
2. Turn off the power on the machine and turn it on after a while.
"Turning Off the Power"(P. 34)